EasyManuals Logo

Siemens SINUMERIK 840D Function Manual

Siemens SINUMERIK 840D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
Detailed description
2.2 Protection zones
Basic logic functions: Axis monitoring, protection zones (A3)
56 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Monitoring of overlaid motion
Axes that have been assigned to another channel are not taken into account. The last
position to be approached is taken to be the end position. It is not taken into account whether
the axis has traversed after changing channels.
Behavior in the AUTOMATIC and MDI operating modes
Protection zones are not overrun in Automatic modes:
If the movement in a block is from outside into the protection zone (N30), deceleration is
executed toward the end of the previous block (N20) and the movement is stopped.
If the protection zone is preactivated but not activated by the PLC, machining is
continued (case 1).
If the protection zone is activated or preactivated and activated by the PLC, machining
is stopped (case 2).
If the starting point of the block is inside the protection zone, the movement is not started.
In case of violation of protection zone for the workpiece-related protection zone, the alarm:
10700 "NCK-protection zone in v or MDI violated" or 10701 "channel-specific protection zone
in AUTOMATIC or MDI violated" is given.
1
1 1 1 1 1
1
1
1
1
Y
W
)RUSUHDFWLYDWHG
SURWHFWLRQ]RQH
QRWDFWLYDWHGE\3/&
FDVH
)RUSUHDFWLYDWHGSURWHFWLRQ]RQH
DFWLYDWHGE\3/&
RUIRUDFWLYDWHGSURWHFWLRQ]RQH
DIWHUUHOHDVHRISURWHFWLRQ]RQHFDVH
3URWHFWLRQ]RQH
Figure 2-14 Behavior of the path velocity when entering a protection zone
Overlaying several axis motions
Overlaid motions of external ZO (zero offsets) or DRF are taken into account if they are
executed at a sufficiently early point in time.
If an overlaid motion occurs while a protection zone is active or operative, an alarm is output
as a warning. This alarm has no effect on the machining operation and resets itself if the
transferred motion has been fully taken into account. The PLC interface signal is set at the
same time as alarm 10704:
DB31, ... DBX39.0 (protection-zone monitoring not guaranteed).
Enabling of workpiece-related protection zones
When a workpiece-related protection zone has been violated, the operator can enable it
temporarily with NC start in the AUTOMATIC and JOG modes so that it can be traversed.
This clears the alarm and travels into the protection zone in the AUTOMATIC and MDI
operating modes.

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals