EasyManuals Logo

Siemens SINUMERIK 840D Function Manual

Siemens SINUMERIK 840D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1549 background imageLoading...
Page #1549 background image
Basic logic functions: Reference Point Approach (R1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
3
Table of contents
1 Brief Description ........................................................................................................................................ 5
2 Detailed description ................................................................................................................................... 7
2.1 Axisspecific referencing .................................................................................................................7
2.2 Channelspecific referencing...........................................................................................................9
2.3 Reference point appraoch from part program (G74) ...................................................................11
2.4 Referencing with incremental measurement systems .................................................................12
2.4.1 Chronological sequence ..............................................................................................................12
2.4.2 Phase 1: Traversing to the reference cam...................................................................................13
2.4.3 Phase 2: Synchronization with the zero mark..............................................................................15
2.4.4 Phase 3: Traversing to the reference point..................................................................................21
2.4.5 Buffered actual value ...................................................................................................................24
2.5 Referencing with distancecoded reference marks.......................................................................26
2.5.1 General overview .........................................................................................................................26
2.5.2 Basic parameter assignment .......................................................................................................26
2.5.3 Chronological sequence ..............................................................................................................29
2.5.4 Phase 1: Travel across the reference marks with synchronization .............................................30
2.5.5 Phase 2: Travel to fixed stop .......................................................................................................31
2.6 Referencing with absolute value encoders ..................................................................................34
2.6.1 Information about calibration........................................................................................................34
2.6.2 Calibration by entering a reference point offset...........................................................................36
2.6.3 Adjustment by entering a reference point value ..........................................................................37
2.6.4 Automatic calibration with probe..................................................................................................39
2.6.5 Calibration with BERO .................................................................................................................41
2.6.6 Reference point approach with absolute encoders .....................................................................43
2.6.7 Automatic encoder replacement detection ..................................................................................43
2.6.8 Enabling the measurement system .............................................................................................45
2.6.9 Referencing variants that are not supported................................................................................46
2.7 Referencing by means of actual value adjustment......................................................................47
2.7.1 Actual value adjustment to the referencing measurement system..............................................47
2.7.2 Actual value adjustment to the referenced measurement system...............................................48
2.7.3 Actual value adjustment for measuring systems with distance-coded reference marks .............49
2.8 Referencing in followup mode......................................................................................................50
2.9 Zero mark selection with BERO...................................................................................................54
3 Supplementary conditions ....................................................................................................................... 55
3.1 Large traverse range....................................................................................................................55
4 Examples................................................................................................................................................. 57

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals