Detailed description   
2.12 Block descriptions 
  Basic logic functions: PLC basic program solution line (P3 sl) 
136  Function Manual, 11/2006, 6FC5397-0BP10-2BA0 
Parameter: 
WVar1 = FunctionNumber 
This function number represents a PI service: 
 
1:  
TMCRTO (create tool) 
2:  
TMFDPL (search for empty location for loading): 
3:  
TMMVTL (prepare magazine location for loading, unload tool) 
4:  
TMFPBP (search for location) 
5:  
TMGETT (search for tool number) 
6:  
TSEARC (search for tool) 
7 ... 
10:  
Reserved 
 
WVar2=SemaphorValue 
 
0: 
Reset semaphore 
1: 
Test and set semaphore 
 
 
Parameterization 
Signal  Type  Range of values  Significance 
PIService  ANY  PI.MMCSEM  Set semaphore 
Unit  INT  1, 2 to 10  Channel 
WVar1  INT  1 ... 10  FunctionNumber 
WVar2  WORD  0, 1  SemaphoreValue