Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
175
Configuration steps
Select function of diagnostics block.
Define suitable data for the recording as signal recorder or data triggering.
Find a suitable point or points in the user program for calling the diagnostics FB.
Create a data block for the ring buffer, see call example.
Call the diagnostics FB with parameters in the user program.
In function 1, it is advisable to clear the ring buffer with the "ClearBuf" parameter. When the
recording phase with function 1 is completed, read out the ring buffer DB in STEP7 with the
function "opening the data block in the data view". The content of the ring buffer DB can now
be analyzed.
Call example
FUNCTION FC 99: VOID
TITLE =
VERSION : 0.0
BEGIN
NETWORK
TITLE = NETWORK
CALL FB 29, DB 80 (
Func
:= 1,
Signal_1 :=M 100.0,
Signal_2 :=M 100.1,
Signal_3 :=M 100.2,
Signal_4 :=M 100.3,
Signal_5 :=M 10.4,
Signal_6 :=M 100.5,
Signal_7 :=M 100.6,
Signal_8 :=M 100.7,
NewCycle := TRUE,
Var1 := MB 100,
BufDB := 81,
ClearBuf :=M 50.0);
END_FUNCTION

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals