Detailed description
2.4 Emergency stop acknowledgement
Basic logic functions: Emergency Stop (N2)
12 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Effects
Resetting the emergency stop state has the following effects:
Within the control, the servo enable is set, the follow-up mode deactivated and the
position control activated for all machine axes.
Set interface signals:
DB 31, ... DBB60.5 (position control active).
Set interface signals:
DB11, ... DBX6.3 (Mode group ready).
Reset interface signal:
DB10, DBX106.1 (Emergency stop active).
Alarm: "3000 Emergency Stop" is cleared.
Part program processing is interrupted in all channels of the NC.
PLC and NCK I/Os
The PLC user program must switch the PLC and NCK I/Os back to the state for operation of
the machine.
POWER OFF / ON (supply off / on)
The emergency stop state can also be reset by switching the controller off and back on
(POWER OFF / ON).
Prerequisite: When powering up the control, the interface signal must not be active:
DB10, DBX56.1 (Emergency stop).

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals