8
10.04 Alarms and Messages
8.2
larms in Sho
Mill
8
ï›™ Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Operation/Programming ShopMill (BAS) – 10.04 Edition 8-413
112542
GUD variable not available or too small in the field dimension:
%1
Explanation The required GUD variable was not found during read or write access.
Response Alarm display
Remedy Include the right GUD variables.
112543
Prog. was created with higher software version
Explanation The part program was created with a higher software version than the
existing software version.
Response Alarm display
Remedy Delete the machining operation and, if necessary, program it
elsewhere.
112544
Program cannot be opened. It is already being edited.
Explanation The program is already opened in another editor (e.g. in HMI
Advanced).
Response Alarm display
Remedy Close the program
112546
Program cannot be opened. No read rights on file.
Explanation The file has no read rights for the current access level.
Response Alarm display
Remedy Set the read rights by means of keyswitch or password entry.
112550
Sequential control programming not opened
Explanation The "sequential control programming" option has not been set.
Response Alarm display
The program is opened as G code.
Remedy Buy option.
112604
Connection to PLC broken
Explanation Acknowledgement to the PLC user program, that the connection with
the PCU has been broken off.
Response Alarm display
ShopMill PLC is shut down
Remedy Check PLC user program.
112605
Asynchronous subroutine has not been executed
Note Input values could not be processed correctly by the NC.
Response Alarm display
Remedy Perform NC reset.