Positional Data
3.6 Zero offset frame, (G54 to G57, G505 to G599, G53, G500/SUPA)
Fundamentals
100 Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
Parameters
G54 to G57
Call the second to fifth settable zero offset/frame
G505 ...G599
Call the 6th to the 99th settable zero offset
G53
Non-modal deactivation of current settable zero offset and
programmable zero offset
G500
G500=zero frame, default setting,
(contains no offset, rotation, mirroring or scaling)
Deactivation of settable zero offsets/frames (G54 to G599) until the
next call.
Activation of the total basic frame ($P_ACTBFRAME).
G500 is not 0
Activation of first settable zero offset/frames ($P_UIFR[0]) and
Activation of total basic frame ($P_ACTBFRAME), or a modified basic
frame is activated.
SUPA
Non-modal deactivation, including programmed offsets, handwheel
offsets (DRF), external zero offset and PRESET offset.
G153
Non-modal suppression of settable, programmable and total basic
frame
For more information please refer to Frame section.
Offset of the zero in the Cartesian coordinate system by frames such as
• Programmable zero offset, e.g., TRANS, ATRANS
• Programmable rotations, e.g., ROT, AROT
• Programmable scalings, e.g., SCALE, ASCALE
• Programmable mirrorings, e.g., MIRROR, AMIRROR
Example
In this example, three workpieces, arranged on a pallet according to the zero offset values
G54 to G56, are machined successively. The machining sequence is programmed in
subprogram L47.