Tables
12.1 List of statements
Fundamentals
Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
445
Name Meaning Value Description,
comment
Syntax m/s
3
Group
2
FILESTAT Delivers file status of
rights for read, write,
execute, display, delete
(rwxsd).
STRING,
length 5
Format is
"rwxsd".
FILETIME Delivers time when file
was last accessed and
written
STRING,
length 8
Format is
"dd:mm:yy".
FINEA Motion end when "Exact stop fine"
reached
FINEA=... or
FINEA[n]=...
m
FL Speed limit for
synchronized axes
(feed limit)
Real, without
sign
The unit set
with G93, G94,
G95 is
applicable
(max. rapid
traverse).
FL[axis] =… m
FLIN
6
Feed linear variable (feed linear) Acts on feed
with G93 and
G94.
m 37
FMA Feed multiple axial
Real, without
sign
m
FNORM
1,6
Feed normal to DIN 66025
m 37
FOCOF Deactivate travel with limited
moment/force
m
FOCON Activate travel with limited moment/force m
FOR Counter loop with fixed number of passes
FP Fixed point: Number of
fixed point to be
approached
Integer,
without sign
G75 FP=1 s
FPO Feed characteristic
programmed via a
polynomial
(feed polynomial)
real Quadratic,
cubic
polynomial
coefficient
FPR Identification for rotary
axis
0.001, ...,
999999.999
FPR (rotary axis)
FPRAOF Deactivate revolutional
feedrate
FPRAON Activate revolutional
feedrate