Tables
12.1 List of statements
Fundamentals
470 Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
Name Meaning Value Description,
comment
Syntax m/s
3
Group
2
WHILE
Start of WHILE program loop End:
ENDWHILE
WRITE Write block in file system.
Appends a block to the end of the
specified file.
The blocks are
inserted after
M30.
X Axis real m/n
XOR Logical exclusive OR
Y Axis real m/n
Z Axis real m/n
Legend:
1
Default setting at beginning of program (factory settings of the control, if nothing else programmed)
2
The groups are numbered according to the table in section "List of G functions/preparatory functions".
3
Absolute end points: modal (m);
incremental end points: non-modal (n);
otherwise: modal/non-modal depending on syntax of G function
4
As circle center points, IPO parameters act incrementally. They can be programmed in absolute mode with AC. The
address modification is ignored when the parameters have other meanings (e.g., thread pitch).
5
The keyword is not valid for SINUMERIK 810D.
5
The keyword is not valid for SINUMERIK 810D/NCU571.
7
The keyword is not valid for SINUMERIK FM-NC.
8
The OEM can add two extra interpolation types. The names can be changed by the OEM.
9
Extended address notation cannot be used for these functions.