Appendix
B-44
7176 Backup O/C Pickup L12 (O/C Pickup
L12)
Backup over-
current
OUT * ON LED BO 64 76 2
7177 Backup O/C Pickup L12E (O/C
Pikkup L12E)
Backup over-
current
OUT * ON LED BO 64 77 2
7178 Backup O/C Pickup - Only L3 (O/C
PU 1p. L3)
Backup over-
current
OUT * ON LED BO 64 78 2
7179 Backup O/C Pickup L3E (O/C Pickup
L3E)
Backup over-
current
OUT * ON LED BO 64 79 2
7180 Backup O/C Pickup L31 (O/C Pickup
L31)
Backup over-
current
OUT * ON LED BO 64 80 2
7181 Backup O/C Pickup L31E (O/C
Pikkup L31E)
Backup over-
current
OUT * ON LED BO 64 81 2
7182 Backup O/C Pickup L23 (O/C Pickup
L23)
Backup over-
current
OUT * ON LED BO 64 82 2
7183 Backup O/C Pickup L23E (O/C
Pikkup L23E)
Backup over-
current
OUT * ON LED BO 64 83 2
7184 Backup O/C Pickup L123 (O/C
Pikkup L123)
Backup over-
current
OUT * ON LED BO 64 84 2
7185 Backup O/C Pickup L123E (O/C
PickupL123E)
Backup over-
current
OUT * ON LED BO 64 85 2
7191 Backup O/C Pickup I>> (O/C
PICKUP I>>)
Backup over-
current
OUT * ON LED BO 64 91 2 GI
7192 Backup O/C Pickup I> (O/C PICKUP
I>)
Backup over-
current
OUT * ON LED BO 64 92 2 GI
7193 Backup O/C Pickup Ip (O/C PICKUP
Ip)
Backup over-
current
OUT * ON LED BO 64 93 2 GI
7201 O/C I-STUB Pickup (I-STUB
PIKKUP)
Backup over-
current
OUT * ON
OFF
LED BO 64 101 2 GI
7211 Backup O/C General TRIP com-
mand (O/C TRIP)
Backup over-
current
OUT * * LED BO 64 111 2
7212 Backup O/C TRIP - Only L1 (O/C
TRIP 1p.L1)
Backup over-
current
OUT * ON LED BO 64 112 2
7213 Backup O/C TRIP - Only L2 (O/C
TRIP 1p.L2)
Backup over-
current
OUT * ON LED BO 64 113 2
7214 Backup O/C TRIP - Only L3 (O/C
TRIP 1p.L3)
Backup over-
current
OUT * ON LED BO 64 114 2
7215 Backup O/C TRIP Phases L123 (O/C
TRIP L123)
Backup over-
current
OUT * ON LED BO 64 115 2
7221 Backup O/C TRIP I>> (O/C TRIP
I>>)
Backup over-
current
OUT * ON LED BO 64 121 2
7222 Backup O/C TRIP I> (O/C TRIP I>) Backup over-
current
OUT * ON LED BO 64 122 2
7223 Backup O/C TRIP Ip (O/C TRIP Ip) Backup over-
current
OUT * ON LED BO 64 123 2
7235 O/C I-STUB TRIP (I-STUB TRIP) Backup over-
current
OUT * ON LED BO 64 135 2
7325 CB1-TEST TRIP command - Only L1
(CB1-TESTtrip L1)
Testing OUT ON
OFF
* LED BO 153 25 2 GI
F.No. Description Function Type of Infor-
mation
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Event Log
Type
Information-No
Data Unit (ASDU)
General Interrogation