Appendix
366
7SS52 V4 Manual
C53000-G1176-C182-1
10413 Diff-current supervision Check
Zone L3 (Id-sup CZ L3)
Monitoring OUT on
off
* * LED BO 194 208 1 yes
10415 Diff-current superv. BZ (group
alarm) (Id-sup BZ M)
Monitoring OUT * * * LED BO 194 200 1 yes
10416 Diff-current superv. BZ L1 (group
alarm) (Id-sup BZ L1 M)
Monitoring OUT * * * LED BO 194 201 1 yes
10417 Diff-current superv. BZ L2 (group
alarm) (Id-sup BZ L2 M)
Monitoring OUT * * * LED BO 194 202 1 yes
10418 Diff-current superv. BZ L3 (group
alarm) (Id-sup BZ L3 M)
Monitoring OUT * * * LED BO 194 203 1 yes
10420 15V supply supervision central
unit (15V-superv CU)
Monitoring OUT on
off
* * LED BO 194 212 1 yes
10421 24V supply supervision central
unit (24V-superv CU)
Monitoring OUT on
off
* * LED BO 194 213 1 yes
10422 Battery supervision central unit
(Batt. superv CU)
Monitoring OUT on
off
* * LED BO 194 214 1 yes
10423 Measured value superv. BU
(group alarm) (Meas sup BU M)
Monitoring OUT on
off
* * LED BO 194 216 1 yes
10424 Supply voltage superv. BU (group
alarm) (Supply sup BU M)
Monitoring OUT * * * LED BO 194 215 1 yes
10425 Isolator fault alarm (Isol flt alarm) Monitoring OUT * * * LED BO 194 186 1 yes
10426 Failure of isolator aux. voltage (g.
a.) (Bay DC fail M)
Monitoring OUT * * * LED BO 194 185 1 yes
10427 Isolator fault: run time (group
alarm) (Isol flt run M)
Monitoring OUT * * * LED BO 194 184 1 yes
10428 Isolator position faulty (group
alarm) (Isol flt pos M)
Monitoring OUT * * * LED BO 194 183 1 yes
10429 Failure in auto testing (group
alarm) (Flt autotest M)
Monitoring OUT * * * LED BO 194 210 1 yes
10430 >Blocking of Breaker Failure Pro-
tection (>Blocking BF)
BF-Protection SP on
off
* * LED BI BO 194 164 1 yes
10431 Blocking of Breaker Failure Pro-
tection (Blocking BF)
BF-Protection IntSP on
off
**LEDBO
10432 Breaker Failure Protection
blocked (BF blocked)
BF-Protection OUT on
off
* * LED BO 194 165 1 yes
10433 Breaker Failure/Transfer Trip (g.
a.) (Transf. Trip M)
BF-Protection OUT * * m LED BO 194 180 2 yes
10434 Timing error BF input (group
alarm) (BF BI error M)
BF-Protection OUT * * * LED BO 194 181 1 yes
10435 Timing error BF release (group
alarm) (BF rel error M)
BF-Protection OUT * * * LED BO 194 182 1 yes
10436 Trip command BF (group alarm)
(Trip BF M)
BF-Protection OUT * * * LED BO 194 176 2 yes
10437 Timing error BF impulse input (g.
a.) (BF ImpBI errorM)
BF-Protection OUT * * * LED BO 194 189 1 yes
10439 Trip command BF external (Trip
BF extern)
IEC61850-info OUT * * * LED BO
10440 >TRIP commands blocking
(>TRIP blocking)
Device SP on
off
* * LED BI BO 194 162 1 yes
10441 TRIP commands blocking (TRIP
blocking)
Device IntSP on
off
**LEDBO
10442 TRIP commands blocked (TRIP
blocked)
Device OUT on
off
* * LED BO 194 163 1 yes
10443 BZ blocked selective (g. a.)
(Block BZ sel M)
BB Protection OUT * * * LED BO 194 192 1 yes
FNo. Description Function Type
ofIn-
for-
matio
n
Log-Buffer Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information No.
Data Unit
General Interrogation