Parameter lists
A.3 Diagnostic
SITRANS FUS080 transmitter
Operating Instructions, 07/2012, A5E03059912-02
75
Modbus
Address
Parameter Default
value
Value
range
Access
level
Description
40283 228 Parameter checksum
fault appears
e.g. 0 h 0 ... 65535 Read First time the fault appeared.
Valid only if alarm is enabled
40286 229 Parameter checksum
fault disappears
e.g. 0 0 ... 65535 Read Password to change parameters in the
flowmeter.
Valid only if alarm is enabled
7 230 Low power alarm output
enable
Yes No, Yes R/W Select 'Yes' to enable active alarm on
alarm output / call-up
40289 231 Low power fault hours e.g. 0 h 0 ... 65535 Read Total hours fault active.
Valid only if alarm is enabled
40290 232 Low power fault counter e.g. 0 0 ... 65535 Read Total number of faults.
Valid only if alarm is enabled
40291 233 Low power fault appears e.g. 0 h 0 ... 65535 Read First time the fault appeared.
Valid only if alarm is enabled
40294 234 Low power fault
disappears
e.g. 0 0 ... 65535 Read Last time the fault disappeared.
Valid only if alarm is enabled
8 235 Flow overflow alarm
output enable
Yes No, Yes R/W Select 'Yes' to enable active alarm on
alarm output / call-up
40297 236 Overflow fault hours e.g. 0 h 0 ... 65535 Read Total hours fault active.
Valid only if alarm is enabled
40298 237 Overflow fault counter e.g. 0 0 ... 65535 Read Total number of faults.
Valid only if alarm is enabled
40299 238 Overflow fault appears e.g. 0 h 0 ... 65535 Read First time the fault appeared.
Valid only if alarm is enabled
40302 239 Overflow fault
disappears
e.g. 0 0 ... 65535 Read Last time the fault disappeared.
Valid only if alarm is enabled
9 240 Pulse A overload alarm
output enable
Yes No, Yes R/W Select 'Yes' to enable active alarm on
alarm output / call-up
40305 241 Pulse A overload fault
hours
e.g. 0 h 0 ... 65535 Read Total hours fault active.
Valid only if alarm is enabled
40306 242 Pulse A overload fault
counter
e.g. 0 0 ... 65535 Read Total number of faults.
Valid only if alarm is enabled
40307 243 Pulse A overload fault
appears
e.g. 0 h 0 ... 65535 Read First time the fault appeared.
Valid only if alarm is enabled
40310 244 Pulse A overload fault
disappears
e.g. 0 0 ... 65535 Read Last time the fault disappeared.
Valid only if alarm is enabled
10 245 Pulse B overload alarm
output enable
Yes No, Yes R/W Select 'Yes' to enable active alarm on
alarm output / call-up
40313 246 Pulse B overload fault
hours
e.g. 0 h 0 ... 65535 Read Total hours fault active.
Valid only if alarm is enabled
40314 247 Pulse B overload fault
counter
e.g. 0 0 ... 65535 Read Total number of faults.
Valid only if alarm is enabled
40315 248 Pulse B overload fault
appears
e.g. 0 h 0 ... 65535 Read First time the fault appeared.
Valid only if alarm is enabled