A5E33329501 SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS Page 13
mmmmm
Installing and Mounting
Mounting the remote lid
1. Using the template provided, cut out the necessary hole for the remote LUI display
lid. Place the gasket inside the lid, aligning the mounting holes. Align the back of the
remote display lid with the panel hole cut-out. Mark and drill four holes in the
mounting surface for the four screws (provided).
2. Fasten with a screwdriver and wrench.
Please note:
Recommended mounting: mount to panel, up to 5 m from the device. If alternate
mounting surface is used, it MUST be able to support four times the weight of the
device.
Pipe mount
For a more detailed dimension drawing, see
SITRANS LUT400 Dimensions
on page 255.
Note: Remote mounted lid can be mounted up to 5 m from the device using two
optional cable extensions (each 2.5 m in length). For instructions on how to con-
nect an extension cable, see
Remote mounted lid with extension cable
on page
29.
Note: Recommended torque on fastening screws for good seal:
•1.1 N m
•10 in-lbs
Note: Fasteners included: M5 screw, seal washer, M5 flat washer and nut. These
fasteners are required to maintain IP65 rating on remote lid.
mounting back plate
u-bolt
saddle
clamp
enclosure with optional display lid
pipe
Note: Pipe mount fasteners not included.