SIGLENT SDM3045X Specifications

General IconGeneral
Display4.3 inch TFT-LCD
Digits4.5
Resistance MeasurementYes
Capacitance MeasurementYes
Frequency MeasurementYes
InterfaceUSB Device, USB Host, LAN
DC Voltage Range200 mV to 1000 V
AC Voltage Range200 mV to 750 V
DC Current Range10mA to 10A
AC Current Range10mA to 10A
Resistance Range100Ω to 100MΩ
Basic DC Voltage Accuracy±0.025%+5
Basic Capacitance Accuracy1%
Basic Frequency Accuracy0.01%
Power Supply100 V ~ 240 V AC, 50 Hz/60 Hz
Sampling Rate150 Sa/s
Capacitance Range2 nF / 10 mF
Temperature Range-200 °C ~ 1000 °C, -328 °F ~ 1832 °F

Summary

Chapter 1 Quick Start

General Inspection

Inspect shipping container, instrument, and accessories for damage or missing items.

Front Panel

Overview of the instrument's front panel controls and displays.

Back Panel

Description of interfaces and connectors on the instrument's back panel.

User Interface

Explanation of single and dual display modes and interface elements.

Chapter 2 Function and Operation

To Select Measurement Range

Methods for selecting automatic or manual measurement ranges for readings.

Basic Measurement Functions

Overview of fundamental measurement capabilities like Voltage, Current, Resistance.

To Measure DC Voltage

Step-by-step guide for measuring DC voltage, including connections and setup.

To Measure 2-Wire/4-Wire Resistance

Instructions for measuring resistance using 2-wire and 4-wire methods.

To Measure Frequency or Period

Steps to measure signal frequency and period using the instrument.

Math Function

Details on using math functions like Statistics, Limits, dBm, dB, and Relative Value.

Trigger

Configuration and operation of Auto Trigger, Single Trigger, and External Trigger modes.

Chapter 3 Application Examples

Example 1: Reading Statistic Functions

Demonstrates how to use the instrument's statistic functions during measurements.

Example 2: To Eliminate Leads Impedance

Shows how to use relative operation to remove lead impedance errors.

Example 5: Limits Test

Practical guide on setting and performing limits tests with the instrument.

Chapter 4 Measurement Tutorial

True RMS AC Measurement

Explanation of true RMS AC measurement principles and accuracy.

Crest Factor Errors (non-sinusoidal inputs)

Discusses how waveform shape and crest factor affect measurement accuracy.

Loading Errors (AC Voltage)

Details on input impedance and capacitance effects on AC voltage measurements.

Chapter 5 General Troubleshooting

Chapter 6 Appendix

Appendix A: Accessories

List of standard accessories included with the instrument.

Appendix B: Warranty summary

Summary of the product warranty period and terms.

Appendix C: Daily Maintenance and Cleaning

Guidelines for proper maintenance and cleaning of the instrument.

Appendix D: Contact SIGLENT

Contact information for SIGLENT support and services.