EasyManua.ls Logo

SIGRIST TurBiScat PM 40 - User Manual

SIGRIST TurBiScat PM 40
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TurBiScat PM 40
sigrist.com
Operating Manual

Table of Contents

Other manuals for SIGRIST TurBiScat PM 40

Questions and Answers

SIGRIST TurBiScat PM 40 Specifications

General IconGeneral
Wavelength860 nm
Measuring Range0.000 to 4000 NTU (user selectable ranges within this limit)
Accuracy±0.01 NTU, whichever is greater
Response TimeAdjustable
Operating Temperature-20 to +60 °C
Protection ClassIP65
Power Supply24 VDC
Output Signal4 to 20 mA, Modbus
Detection Angle90°
Process ConnectionFlange
Process Temperature Range-20 to +110 °C (-4 to +230 °F)
CertificationsCE

Summary

Imprint Information

Manufacturer Contact and Address

Provides company details, address, and contact information for Sigrist-Photometer AG.

Document Overview and Compliance

Covers copyright provisions, standards adherence, and liability disclaimers.

About This Document

Purpose and Scope of Manual

Explains the manual's intent to ensure safe and efficient device operation throughout its lifecycle.

Safety, Compliance, and Conventions

Covers liability for non-compliance, target audience, conformity, and representation conventions.

Document Symbols and Text Markings

Explains symbols for actions, reactions, cross-references, editable/read-only functions, menus, and buttons.

Your Safety

Intended Use and Application Areas

TurBiScat PM 40 is for liquid turbidity measurement, applicable in food and beverage industries.

Hazardous Area Restrictions

DANGER: Device must not be operated in potentially explosive atmospheres or with explosive substances.

Foreseeable Misuse and Liability

DANGER: Incorrect usage can lead to injuries or damage. Manufacturer disclaims liability for misuse.

Understanding Warning Levels

Explains the tiered warning system: Danger, Warning, Caution, and Note, detailing their severity.

Residual Risk Identification

Details risks including electrical hazards, pressure, liquid leaks, chemical exposure, and unauthorized access.

Device Specifications

Device Overview and Components

Visual representation of the TurBiScat PM 40, with and without SiDis AD 40, highlighting key parts.

Identification and Nameplate Details

Details the information on the device nameplate and the scope of delivery for accessories.

Installation and Mounting

General Mounting Guidelines

Advises on placement, distance from light sources, and suitable pipe fitting positions.

Photometer and SiDis AD 40 Mounting Positions

Covers mounting positions, VARINLINE® connection, and wall mounting for SiDis AD 40.

Mounting Plate Adjustment

Describes the process to rotate the mounting plate by 90° if needed for SiDis AD 40.

Electrical Installation and Connectivity

Electrical Safety and Connection Requirements

DANGER: Improper voltage connection is life-threatening. Emphasizes professional installation and disconnectors.

Communication Module Identification and Pinouts

Explains how to identify communication modules (EG_IO, EG_PoE, etc.) and their basic connection types.

EG_IO Module Wiring and I;O Configuration

Details digital inputs, outputs, current outputs, and the wiring diagram for the EG_IO module.

EG_PoE and EG_Profibus Module Specifications

Details PoE connectivity, cable characteristics, and pin assignments for EG_Profibus.

EG_Profinet Module Pinout Details

Provides pin assignments for Male (A), Female (B), and Female (C) connectors for the EG_Profinet module.

Operation

Local Display Navigation and Data Viewing

Explains how to navigate the local display using gestures to view measurement data.

SIGRIST-Webinterface Overview

Introduces the web interface for parameterization and lists its key features.

Commissioning and Initial Setup

Device Setup and Display Orientation

Covers initial mounting, voltage, and how to rotate the device display for optimal viewing.

WLAN and Mobile Device Connection

Details activating WLAN and connecting a mobile device for web interface access.

Accessing and Logging into Web Interface

Guides on accessing the SIGRIST-Webinterface via URL/QR code and logging in securely.

Settings

Photometer Display and Sensor Status

Manages display modes, sensor status, and general status indicators on the photometer.

Display Modes and Graphic Configuration

Details start, measurement, and graphic display configurations, including scaling and resolution.

Network and Communication Module Status

Displays status for WLAN, IO, and PoE modules, including IP and DHCP information.

Profinet, Profibus, and WLAN Connection Settings

Configures Profinet/Profibus modules and manages WLAN network connections.

Status, Limits, and Contact Information

Shows device status, warning messages, limit value settings, and manufacturer contact details.

System Information and Software Versions

Displays device type, serial number, operating hours, and software versions for diagnostics.

Sigrist-Webinterface Homepage and Initial Steps

Guides through the web interface homepage, menu, language selection, and initial configuration steps.

9.3 Simple Configuration Mode

General Configuration Parameters

Sets region, time, display rotation, access code, and device designation.

Communication Module EG_IO Configuration

Configures function, integration time, and output ranges for the EG_IO module.

EG_IO Output and EG_PoE Module Settings

Configures EG_IO output ranges and EG_PoE network parameters like IP address and DHCP.

EG_Profinet Module and Simulation Settings

Configures EG_Profinet network parameters and enables device simulation for testing.

9.4 Advanced Configuration Mode

Menu: Recalibration and History

Guides through recalibrating channels C1-Cn, setting nominal and actual values, and viewing history.

Menu: System Information and Faults

Displays device type, serial number, and fault information for diagnostics.

System Info, Firmware Updates, and Backup;Restore

Provides software versions, operating hours, firmware update options, and backup/restore functions.

IO Module EG_IO General and Channel Configuration

Configures general IO parameters, external inputs, and specific functions for IO 1-6.

IO Module EG_IO Output and Input Settings

Configures EG_IO output and input parameters, including signal types and priorities.

IO Module EG_PoE and EG_Profibus Configuration

Configures EG_PoE network settings and EG_Profibus parameters like slave number.

IO Module EG_Profinet and WLAN Settings

Configures EG_Profinet network parameters and general WLAN settings.

Menu: Display Settings

Customizes display parameters like values, brightness, rotation, and standard display.

Menu: Simulation, Sensor Check, and Logger

Configures device simulation, sensor checks, and data logging intervals.

Menu: System and Meas. Channels Configuration

Configures system parameters, date format, and measurement channel linearisation.

Menu: Math. Channels Configuration

Defines mathematical channel functions and their parameters for advanced calculations.

Logger Diagram and Measuring Info

Displays logger data graphically and provides current measuring information.

Field Bus Configuration and Fault Codes

Configures field bus communication and lists available fault codes for troubleshooting.

Servicing

Maintenance Schedule and Recommendations

Outlines the recommended maintenance intervals and tasks for optimal device performance.

Replacing Desiccant

Provides instructions for replacing the desiccant to prevent internal condensation.

Cleaning the Sensor Head

Details the procedure for cleaning the sensor head windows safely and effectively.

Calibration Check Procedure

Guides through the calibration check process, including overview of control unit and safety warnings.

Cleaning and Preparing the Control Unit

Provides instructions for cleaning the control unit and preparing it for calibration.

Control Unit Filling and Calibration Execution

Details filling the control unit with test medium and executing the calibration check.

Replacing Seals and Spare Parts

Instructions for replacing seals on the VARINLINE® connection and information on spare parts.

Troubleshooting

Isolating Malfunctions and General Measures

Provides steps for isolating malfunctions, checking voltage, analyzing errors, and performing checks.

Understanding Warning and Priority Error Messages

Explains how warning and priority error messages are displayed and how to interpret them.

Warning Message Details

Lists specific warning messages, their descriptions, and possible causes.

Detailed Warning and Fault Message Descriptions

Provides detailed descriptions and possible causes for various warning and fault messages.

Prio Fault Message Descriptions

Lists priority fault messages, their descriptions, and potential causes requiring service engineer intervention.

Specification Sheet

TurBiScat PM 40 General Specifications

Details electrical, mechanical, material, and environmental specifications for the TurBiScat PM 40.

TurBiScat PM 40 Measurement Details

Provides specifications for wavelength, measuring range, resolution, reproducibility, and linearity.

SiDis AD 40 and Communication Modules Specifications

Lists specifications for the SiDis AD 40 and various communication modules (EG_IO, EG_PoE, EG_Profibus).

Returns

Return Procedures and Hazardous Media Handling

Outlines procedures for returning devices, including RMA forms and handling hazardous media.

Decommissioning and Storage

Component Preparation for Storage

Details steps to prepare device components for proper storage, including cleaning and sealing.

Component Storage Conditions

Specifies recommended conditions for storing electronic components, including temperature and environmental factors.

Disposal

Material Disposal Options

Provides a table outlining disposal options for different material categories according to regulations.