Home
Simplex
Smoke Alarm
4002
Simplex 4002 User Manual
5
of 1
of 1 rating
48 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
4002
MAIN
C.P.U.
COMPONENT
LOCATIONS
Fuse
Fl,
3
Amp
Annunciator
Voltage
(
+
24VDC)
DIP
Switch,
SW1
1
Annunciator
Supervision
,DIP
Switch,
SW3
Serial
Annunciator
Program
Switch
DIP
Switch,
S
W2
Program
Switch
DIP
Switch,
SW7
Program
Switch
Fuse
F2
8
Amp
Main
Power
Fuse
F9,3
Amp
+
‘“/““”
Conmctor
P4-
Transformer
Cable
I
\
Connector
P5
Fuse
F6,3
Amp
Battery
Cable
Signal
Circuit
2
Pins
+
and
-
Fuse
W,
3
Amp
Signal
Circuit
1
,
Fuse
F5,3
Amp
Aux
1
Rela
‘Y
-Fuse
F4,3
Amp
AUX
2
Rel;
ay
Figure
4
-
Component
Locations
15
Technical Manuals Online! - http://www.tech-man.com
16
18
Table of Contents
Table of Contents
3
Description
5
Indicators
6
Pushbuttons
6
Toggle Switches
6
Alarm Condition
8
Normal Condition
8
Operating 4002 Optional Equipment
8
Trouble Condition
8
Control Panel Operating Instructions
9
Trouble Conditions
9
Sprinkler Activation
10
Battery Test
11
LED and Trouble Buzzer Test
12
Manual Evacuation Test (Drill)
12
Graphic Representation of Audible Zone Codes
13
What to Do in Case of Trouble
14
System Troubleshooting Chart
14
Introduction
18
General Notes
18
Installation Checklist
19
Back Box Installation
20
System Wiring Specifications
21
Notification Appliance Wiring
22
Control Circuits
22
Incoming Power
23
Earth Detection (Ground)
23
Mounting and Wiring Peripheral Devices
23
Style 6
23
Style D
24
Checking System Wiring
24
Style B Initiating Device
24
Style D Initiating Device
24
Sprinkler Tamper Switch Circuit
24
Style y Notification Appliance
24
Style Z Notification Appliance
25
Re-Mounting Electronic Components in Back Box
25
Terminations of System Wiring
26
Initiating Device Circuit
26
Annunciator Output Circuit
26
City Relay
26
Special Zone Inputs
26
Connect Power to System
26
2120 Connection
27
Wiring
27
Setting DIP Switches, Swl, SW2 and SW3
27
Fan Control Module
29
Definitions of System Functions
29
Normal Operation
29
Alarm Verification
29
Coded Input on Zone 1
30
Waterflow on Zone 7
30
Sprinkler Supervision on Zone 8
30
Signal Cutoff after 10 Minutes
30
Signal Silence Inhibit
31
2120 Connection Present in System
31
Walk Testtm Mode
31
Manual Evacuation Switch Enabled/Disabled
31
Signal Coding
31
Selective Signal Circuit Operation
32
ESP Program Mode
32
Customer Information
33
Re-Mounting Retainer and Door
33
Walk Testtm
33
Glossary of 4002 Fire Alarm System Terms
34
APPENDIX A -Expanded Simplex Programmingoption
35
APPENDIXA - Expanded Simplex Programming Option
35
Selective Signal Circuit Operation
35
Selective Relay Control Operation
35
Selective Fan/Damper Control Relay Operation
35
Selective Door Holder Relay Control
36
Cross Zoning
36
Master Code
36
Multiple Tamper Zones
36
Non-Alarm Monitor Point Operation
36
Non-Latching Monitor Point Operation
36
Selective Bypass Control Switch Operation
36
Selective Switch Operation
36
Stage L/Stage 2 Operation or Pre-Signal Operation
36
Timing Functions
36
2120 Non-Default Operation
37
Elevator Recall with Alternate Floor
37
PNIS Zone Coding
37
Point Sensing
37
RCU Switch Non-Default Operation
37
SCU Point Matrix (Zone Grouping)
37
System Reset (Special Operation)
37
APPENDIX B - Fan Control Module
38
Features
38
Field Connections
38
Panel Connections
38
Switches
38
DIP Switch SW1
38
Switch SW2
39
Switch SW3
40
DIP Switch SW4
40
DIP Switch SW3 on CPU Module
40
Diagram
41
Wire Length Chart in Feet
42
Other manuals for Simplex 4002
Instructions
24 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Simplex 4002 and is the answer not in the manual?
Ask a question
Simplex 4002 Specifications
General
Voltage
24 VDC
Temperature Range
32°F to 120°F (0°C to 49°C)
Humidity Range
Up to 93% RH, non-condensing
Interconnect Capability
Yes
Compliance
UL
Related product manuals
Simplex 4004
36 pages
Simplex 4005
52 pages
Simplex 4098-9019
10 pages
Simplex 2098-9207
24 pages