EasyManua.ls Logo

Simrad AP28 - SimNet Configuration and Groups

Simrad AP28
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup at installation | 99
If the auto-setting does not perform properly due to high
inertia from the wheel or a loose steering gear, it can be
adjusted manually.
Find the lowest possible value that will prevent the
rudder from continuous hunting. A wide deadband will
cause inaccurate steering. It is recommended to check
rudder stability in AUTO mode when the boat is moving
to get pressure on the rudder.
Range Change per step Default Units
AUTO, 0.1 – 4.0 0.1 AUTO °
The rudder deadband setting is not available when the
autopilot is configured for Virtual feedback.