13. Attach the right end of the Recoater’s transmission cable to the plate, using the
cable lug and a screw.
14. Insert the left side of the Recoater’s transmission cable, with the spring and two
spacers, in order to chock the mechanism.
15. Softly tensing, screw back the right side of the Recoater’s transmission cable with
the plate to the printer’s housing (remember that the knot has to be hidden
between the housing and the plate). The plate should touch the housing.
16. Screw the left side of the wire with the plate to the printer case (remember that the
two spacers and the spring should be inside the opening).
17. Attach and screw back the Recoater casing.
F. Technical support
The latest information, technical support, and versions of the manual are available in the
Support tab of the Sinterit Sp.z.o.o. company website or by contacting us through email:
contact@sinterit.com or phone: +48 570 967 860.
The list of distributors and technical support in specific countries can be found at
www.sinterit.com.
13. Working processes with the powders
A. Supplies information
When working with the polyamide powder or other designated printer powder for the Sinterit
Lisa Printer, always wear protective kit attached to the above-mentioned device (glasses,
gloves, dust mask).
WARNING! When working with a polyamide powder, avoid inhalation,
swallowing or contact with skin and eyes.
- If the PA12 Smooth powder is inhaled, move to a place with fresh air
and gargle thoroughly with plenty of water. If coughing develops,
contact a physician.
- If you eat any PA12 Smooth powder, rinse your mouth with water and
drink 1-3 glasses of water to dilute stomach contents. If necessary,
contact your doctor.
- If the PA12 Smooth powder gets in your eyes, rinse them thoroughly
with water. In case of persisting eye irritation, contact a physician.