209
229042ABASJ46 AJ+, SJ46 AJ, SJ51 AJ
Platform Section 5 – Procedures
5.2-11 SCM Calibration - ANSI/CSA
Tare weight calibration sets the unladen weight of the
platform. It is the weight of an empty platform that the
SCM subtracts from the gross weight reading of the
load cell, giving a new zero (net) weight to start from
when measuring the contents of the platform.
Net weight = Gross weight - Tare weight
Net weight: the weight of the platform.
Gross weight: the total weight as measured by the
load cell.
Tare weight: the weight of the empty platform as set
by the tare weight calibration.
1. Make sure the platform is level.
2. Remove all items from the platform, including
optional attachments.
3. Make sure the capacity derate switch
1
is
in the full capacity position, and the capacity
derate light
2
is not on.
TM
1
TM
1
2
+
+
2
4. Do the calibration procedure from the SCM
3
in the base control box. Follow the flowchart on
the next two pages.