1. Swipe from left to right until the “Heater Control ON/OFF” setting comes
into view.
2. Tap the round touch sensor to enter the “Heater Control ON/OFF” setting.
“Up” and “down” arrows will appear on the right side of the screen.
3. The display will read, “BREW”; use the arrows to toggle between brew
tank heater “on” and “off”, then tap the round touch sensor to confirm
setting.
4. The display will read, “STEAM”; use the arrows to toggle between steam
tank heater “on” and “off”, then tap the round touch sensor to confirm
setting.
5. The “Heater Control ON/OFF” setting will reappear. To continue “Advanced
Setting” sub-menu navigation, swipe from left to right. To exit menu
navigation, move the brew actuator to the “pre-brew” or “full brew”
position.
Temperature
Machine temperatures may be displayed in degrees Celsius or Fahrenheit. After
completing the steps above to access the “Advanced Setting” sub-menu, specify
preference with the following steps.
1. Swipe from left to right until the “Temperature” setting comes into view.
2. Tap the round touch sensor to enter the “Temperature” setting. “Up” and
“down” arrows will appear on the right side of the screen.
3. The display will read, “C” (Celsius) or “F” (Fahrenheit), which indicates the
current setting. Use the arrows to toggle between “C” and “F”, then tap
the round touch sensor to confirm setting.
4. The “Temperature” setting will reappear. To continue “Advanced Setting”
sub-menu navigation, swipe from left to right. To exit menu navigation,
move the brew actuator to the “pre-brew” or “full brew” position.
Set PID Values
Proportional-integral-derivative algorithm parameters assist in accurate water
heating and may be adjusted individually. After completing the steps above to
access the “Advanced Setting” sub-menu, adjust parameters with the following
steps.
1. Swipe from left to right until the “Set PID Values” setting comes into view.
2. Tap the round touch sensor to enter the “Set PID Values” setting. “Up”
and “down” arrows will appear on the right side of the screen, as well as
two (2) temperature readings: set temperature (top-right) and actual
temperature (top-left).
The set brew temperature may not be changed at this time. To adjust,
see instructions under “Using Slayer > Adjust Brew Tank Temperature”
on page 30.
3. Three (3) values will display beneath the two (2) temperature readings.
To change, tap the touch sensor beneath each value, then use the arrows
to adjust incrementally.
4. Tap the round touch sensor to confirm settings.