5. The display will read, “Save? UP=Y, DN=N”. To save changes, tap the “up”
arrow; to cancel changes, tap the “down” arrow.
6. The “Set PID Values” setting will reappear. To continue “Advanced Setting”
sub-menu navigation, swipe from left to right. To exit menu navigation,
move the brew actuator to the “pre-brew” or “full brew” position.
IMPORTANT: To ensure optimal performance, the PID values are set at the
studio to “200.2.0”. Changing these values will affect the performance of
Slayer’s heating system and may cause overheating and damage. Do not
manipulate without first reading this manual in its entirety, then consulting your
Slayer representative, reseller, or qualified service personnel. Any changes to
this value, whether intentional or accidental, can be corrected by restoring the
factory tuned settings per the “Restore / Save Settings” instructions under
“Using Slayer > Advanced Settings” on page 37.
Brew Temp Offset
An offset value is used to compensate for physical variations between
temperature probes and to calibrate for accurate water heating. After completing
the steps above to access the “Advanced Setting” sub-menu, adjust the brew
temperature offset value with the following steps.
1. Swipe from left to right until the “Brew Temp Offset” setting comes into
view.
2. Tap the round touch sensor to enter the “Brew Temp Offset” setting. “Up”
and “down” arrows will appear on the right side of the screen, as well as
the real-time temperature reading (lower-left) and the current offset
value (lower-right).
‣
The set brew tank temperature may not be changed at this time. To
adjust, see instructions under “Using Slayer > Adjust Brew Tank
Temperature” on page 30 .
3. Use the arrows to adjust the brew temperature offset value in one-unit
(1-unit) increments, then tap the round touch sensor to confirm setting.
‣
Each unit represents a 0.01ºC change from the pre-calibrated settings
of your machine. For example, an offset value of “28” indicates a
variation of 0.28ºC (28 x 0.01 = 0.28) from pre-calibration.
‣
The brew temperature offset may be a positive or negative value.
4. The “Brew Temp Offset” setting will reappear. To continue “Advanced
Setting” sub-menu navigation, swipe from left to right. To exit menu
navigation, move the brew actuator to the “pre-brew” or “full brew”
position.
IMPORTANT: The brew temperature offset is set at the studio to ensure optimal
performance. Do not manipulate without first reading this manual in its entirety,
then consulting your Slayer representative, reseller, or qualified service
personnel. Any changes to this value, whether intentional or accidental, can be
corrected by restoring the factory tuned settings per the “Restore / Save
Settings” instructions under “Using Slayer > Advanced Settings” on page 37.!