14.Reinstall steam seat and spring.
15.Apply teflon tape to the threads of the brass nut.
16.Use wrench to secure steam valve body; use second wrench to tighten
brass nut.
17.Reconnect the steam tubes to the valve and steam tank.
18.Reattach the steam actuator hub and shoulder bolt.
Replacing Water Level Probe
Parts and tools:
Replacement water level probe (part #30000-50170)
Wrench
Teflon tape
Procedure:
1. Use a wrench to secure the larger of the two nuts at the base of the
probe, then hold the nut in place and spin the probe off of the wire. Set
aside.
2. Apply teflon tape to the threads of the nuts.
3. Screw a new probe onto the wire.
4. Reinstall probe.
For additional assistance with this procedure, refer to parts diagrams
on pages 58-74.
Replacing Brew Actuator Bearing
Parts and tools:
Replacement brew actuator bearing (oilite bushing, part #10000-16200)
Flat-head screwdriver
1/4” allen key
Phillips-head screwdriver
Procedure:
1. Use a phillips-head screwdriver to loosen and remove the three (3) bolts
from the brew cap; set aside.
2. Carefully, lift to remove brew cap.
Several small parts sit underneath the brew cap: one (1) stainless
finder washer, one (1) bayonet bolt, one (1) tongue assembly, one (1)
disc spring, one (1) valve stem, and three (3) group cover spacers.
Note their original positions and ensure that they are not moved.
3. A plastic spacer is set in the underside the brew cap; remove and set
aside.
4. Use a flat-head screwdriver to loosen and remove the lock screw from the
top of the brew actuator; set aside.
5. Loosen and remove the locking nut with a 1/4” allen key; set aside.
A spacer sits underneath the locking nut; ensure that it is not lost.
6. Lift to remove brew actuator; set aside.
51

Table of Contents

Other manuals for Slayer Single Group

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Slayer Single Group and is the answer not in the manual?

Slayer Single Group Specifications

General IconGeneral
Boiler TypeDual Boiler
Brew Temperature ControlPID
Groups1
Pre-infusionProgrammable
Voltage110V/220V
Water SourcePlumbed or Reservoir
Pump TypeRotary