Page #27 background imageLoading...
Page #27 background image
- 26 -
24V
0V
Controller
power supply
Controller
power supply
(2) Example circuit 2 - multiple controllers
If the system where this controller is installed has a stop circuit for whole system, or if the system has
multiple controllers with individual power supply, relay contacts should be made between the 24 VDC
controller power supply and the EMG terminal of the power supply plug.
Caution
When shutdown is input, the controller stops with maximum deceleration, then the motor is turned off.
24V
0V
BK RLS
EMG
C 24V
M 24V
0V
Power supply plug
(the 1
st
controller)
Power supply plug
(the 2
nd
controller)
Power supply plug
(the 3
rd
controller)
24V
0V
Controller
power supply
(Circuit example: The figure below shows the stopped state.)
24 VDC
Ry
0V
stop switch
Ry
Surge suppressor
Reset switch
for stop
Ry
Ry
Ry
BK RLS
EMG
C 24V
M 24V
0V
BK RLS
EMG
C 24V
M 24V
0V

Table of Contents

Other manuals for SMC Networks LECP6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECP6 Series and is the answer not in the manual?

SMC Networks LECP6 Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECP6 Series
CategoryController
LanguageEnglish

Related product manuals