- 40 - 
 
7.3 Return to origin parameter 
The “Return to origin parameter” is the setting data for the return to origin operation. 
 
Details of Return to origin parameter 
Activation: “XX” = Become effective just after recorded into the controller, 
“X” = Become effective after restarting the controller, 
“-” = The parameter cannot be changed (fixed value). 
Sets the direction of return to origin operation. 
Even if “ORIG direction” is changed, direction of + to - of 
step data is not changed. 
●Default value 
 
Electric actuator                                          Electric actuator 
 
 
 
The setting for the return to origin operation 
pushing origin operation [Stop] 
limit switch origin [Sensor] 
A pushing force level at which to set the origin. 
This is the fixed value for this controller 
(It should not be changed). 
The allowable speed to move to origin. 
The acceleration and deceleration during find origin. 
This is the fixed value for this controller 
(It should not be changed). 
The setting for ORIG sensor 
The origin sensor is not effective. [Disable] 
The origin sensor is N.O type. [N.O]. 
The origin sensor is N.C type. [N.C.] 
This is the fixed value for this controller. 
(it should not be changed) 
Undefined parameter 
No.21 
*1)  The  range varies  depending  on  the  electric  actuator.  Please  refer  to  the  manual  of  the  electric 
actuator for more details.   
-200mm    -100mm    0mm 
Origin 
 
●Value changed from 
the default value