- 35 -
7. Setting Data Entry
In order to move the electric actuator to a specific position, it is necessary to setup the patterns of
operations with the controller setting kit or the teaching box. This setup data input by the controller setting
kit or teaching box will be recorded in the memory of the controller.
For the controller setting kit and the teaching box, there are two available modes. The appropriate mode
can be selected depending on the purpose.
● Easy mode
In Easy mode, the electric actuator can be started by entering only a limited number of settings
with the controller setting kit and the teaching box.
The combination of settings you need to set up will change depending on the type of the electric
actuator. (combination of data can be selected.)
● Normal mode
In Normal mode, a more detailed setup can be made (conditions for the electric actuator
and controller, etc.) than in Easy mode.
You can change three kinds of setting data, “Step data,” “Basic parameter” and “Return
to origin parameter” in this mode.
7.1 Step data
Step data is the actual data relating to the operation of the electric actuator.
There are 64 patterns of step data. Each of them has 1 item to be set.
Each step data will become effective as soon as it is written to the controller.
Example) Step data of the controller setting kit [Normal mode]