- 56 -
Err overflow
(1-196)
E
Power off
<Contents>
An overflow of the position error counter inside of the controller
is occurred.
<Countermeasure>
Make sure there are no obstructions that interfere with the
electric actuator movement. Also, make sure that the load,
speed, acceleration and deceleration are within the range of the
electric actuators.
Memory ALM
(1-197)
E
Power off
<Contents>
An error of the EEPROM is occurred.
<Countermeasure>
Please contact SMC.
(The write limit of the EEPROM is roughly 100,000 times)
CPU ALM
(1-198)
E
Power off
<Contents>
The CPU is not operating normally.
(It is possible that the CPU or surrounding circuits is failed or a
malfunction of the CPU is occurred due to an electric noise).
<Countermeasure>
If the alarm cannot be deactivated even after the power is
reapplied, please contact SMC.
*1) Alarm clear method for controller version below SV1.00: input RESET→SVON→SETUP

Table of Contents

Other manuals for SMC Networks LECP6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECP6 Series and is the answer not in the manual?

SMC Networks LECP6 Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECP6 Series
CategoryController
LanguageEnglish

Related product manuals