32
Xon / Xoff
Select
off or on
Factory default: off
Factory default
Choices
Do not execute: Customized settings on the measurement location remain
intact
Execute: Resets interface to factory defaults.
4
Interface Port 3
(see interface description 470.508.090 for more details)
Use of interface
Select
• none
• 2795.14
• 2795.12+2795.20
• IT
• IT 2 (uni-directional)
• Barcode
• Second/large display
• Digital scale
When already assigned to another interface port, this selection is shown as
locked.
Factory default: none
Baud rate
Select
• 1200
• 2400
• 4800
• 9600
• 19200
• 38400
Factory default: 9600
Data bits
Select
• 7
• 8
Factory default: 8
Parity
Select
• none
• even
• odd
Factory default: none
Xon / Xoff
Select
off or on
Factory default: off
Factory default
Select
Do not execute: Customized settings on the measurement location remain
intact
Execute: Resets interface to factory defaults.