77
Auto
totaling / picking
Select
off or on
On means that only the respectively first item must be saved with the Plus key, all
other items are automatically saved to the totaling memory after weight is placed
on the scale and the scale settles.
Factory default: off
Reset
seq. number
Select
under what conditions the sequential number for totaling / picking is reset
disabled
Deleting the totaling memory
Switching off
Function key (enables a different function key)
Factory default: disabled
Total key function
Select
what functions are assigned to the Total key
Only display totals
The total is displayed after the Total function key is pressed. The user can then
decide whether to delete the totaling memory.
Press the F2 Delete Total key to delete the totaling memory.
Then confirm the security question with YES using the F1 to F3 keys; this is
followed by the total printout.
Display, print, and delete total
After pressing the Total function key, the totals are displayed for 3 seconds
and the memory contents are printed and deleted at the same time. A
new totaling transaction can then be started.
Factory default: Display/Print/Delete
Relief factor
Enter
in d with number keypad
The number of number increments by which the scale must be relieved during the
totaling transaction, therefore allowing the next weight to the saved to totaling
memory. If the scale is not relieved, the weight value is not saved to the totaling
memory, and the error message "Error 55 - Place Weight" is displayed.
Between 0
and 30 number increments can be specified. On 0, totaling is possible as
long as the scale has not settled once.
Factory default: 15 number increments
Display information
field
Select
what data is displayed in the information field
Factory default: Switching between the individually used functions, e.g.
totaling memory, Organization Data Memory, switching functions.
Total: continuous display of totaling memory.
Last item: Continuous display of the last item.
IO control: Continuous display of output and input states
Organization data + database: Continuous display of the organization data
memories.
Fixed tare values: Continuous display of the enabled fixed tare value
memory.
Display barcode: Continuous display of the scanned barcode.
Factory default: Factory default
Factory default
Selecting execute resets all settings to factory default