Indication
ON/ OFF/ P
switch
position
LED color
Comment
Red Green Blue
Inverter firmware
upgrade
ON / P Alternating Alternating Alternating
The upgrade
process can
take up to 20
minutes
Error Any ON
ON/ OFF/
Blinking/
Flickering
ON/ OFF /
Blinking/ Flickering
Refer to Errors
and
Troubleshooting
on page 70
ThefollowingtabledescribesproductionpercentageofACinformationbyLEDcolorandON/OFF/P
switchposition.
Indication
ON/
OFF/ P
switch
position
LED color
Comment
Red Green Blue
Percentage of AC Production:
0 - 33 %
ON (1)
OFF ON OFF
This indicates
power production
as percentage of
rated peak AC
output power
Percentage of AC Production:
33 - 66 %
OFF OFF ON
Percentage of AC Production:
66 - 100 %
OFF ON ON
Chapter 3: Installing the Primary and Secondary Unit(s)
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4