6.4.2 Setting the network parameters
Device address
In order to communicate via RS485 or Ethernet interface the inverter needs a unique
device address on the network.
1. In the "Settings" menu, select the "Device address" parameter.
2. Set the parameter to the required value:
Parameter Description
Device address Address range: 1…249
Configuring the Ethernet interface
In addition to the device address, the following settings must be made to communicate
via Ethernet:
1. In the "Main menu" select the "Network" menu.
2. Select the necessary setting in the "IP-Mode" menu:
Setting Description
DHCP-Client The inverter is a DHCP client and is connected to a network with DHCP
server (factory setting).
Static The inverter is connected to a network with static IP addresses and has
to be congured in accordance with step 3.
3. If appropriate, congure the following parameters. These settings are only required in
“Static” IP mode (see step 2):
Parameter Description
IP IP address (192.168.1.123)
Gateway (192.168.1.1)
TCP Port (1234)
DNS1 Domain Name Server 1 (192.168.1.1)
DNS2 Domain Name Server 2 (192.168.1.1)
Netmask Subnet mask (255.255.255.0)
(in brackets: factory settings)
4. Check whether the indicator for the Ethernet connection appears on the graphics
display (see Section 7.1).