112
8.2.2 Warnings
The status LED ashes orange.
Warning Cause Actions
Temperature limitation The output power is temporarily
reduced in order to limit the
inverter‘s temperature.
Ensure that
the recommended maximum
ambient temperature is not
exceeded; that the cooling ns
are free from dust and dirt.
Fan failure A fan is defective or soiled. Contact the SolarMax Service
Center.
RTC error Date and time in the RTC (real-
time clock) were reset due to a
malfunction.
Set the date and time (see
section 6.4.1). If this problem
occurs frequently, contact the
SolarMax Service Center.
Firmware mismatch The rmware versions of the
inverter controllers do not match.
Contact the SolarMax Service
Center.
Flash error An error has occurred in the ash
memory.
Contact the SolarMax Service
Center.
SPD failure An active signal is present at
the "SPD Monitor" input of the
I/O module (monitoring lightning
protection).
Check the external lightning
protection module (or the
device connected to the "SPD
Monitor" input).
8.2.3 Faults
The status LED lights up orange.
Note
MaxTalk can be used to read out the last error messages.
Status message Cause Actions
Vdc too high The DC input voltage of the
inverter is too high.
Switch off the DC discon-
nector. Check the PV genera-
tor’s conguration.
Ierr too high The ground leakage current has
exceeded the permissible RBCM-
THR limit value.
Check the PV generator.
Ierr step too high The leakage current has exceeded
the admissible RSCM step value.
No mains There is no mains voltage. Check the AC conductor
(fuses).