122
Temperature dependent output reduction
The inverter can feed 100 % of its rated output for an unlimited time up to an ambient
temperature of 45 °C. When operating in ambient temperatures in excess of 45 °C it is
possible that the yield is reduced. For this reason excessive ambient temperature should
be avoided. In the specied ambient temperature range the power output of the SM2000P
will be consistent.
110
100
90
80
70
60
20 10 0 10 20 30 40 45 50 60
SM5000P
SM4600P
SM4000P
SM3000P
SM2000P
Output Pac/Pac nom [%]
Ambient temperature [°C]
Country-specific settings
The factory's default settings for different countries can be viewed in the technical infor-
mation "SSF - Standard specic functions and parameters - Factory settings". This docu-
ment can be downloaded from our website at: www.solarmax.com; Downloads/String
inverters/P series/Manuals.