13
en
4 Installation
4.1 Transport and storage
During transport, attention must be paid to the following aspects:
During transport and any interim storage period, you must ensure that the local
ambient conditions (temperature and humidity) are always within the limit values
specied in the technical data. Any longer term, unattended, and unprotected interim
storage of the inverter in the open must be avoided.
Since this is a two-section package, you must absolutely ensure that the top and the
bottom of the package are glued together when the inverter is returned or
forwarded.
4.2 Siting
Choosing a suitable location for the inverter is decisive for its operating safety as well as
its expected service life and efciency.
When you select an installation site for the inverter please follow these instructions:
DANGER
The inverter and all feed lines must be installed out of reach of children or pets
(especially rodents).
Install the inverter in an environment that is free of ammable gases and uids.
Never install the inverter near combustible materials. The installation base must
be non-combustible.
The installation substrate must have sufcient structural strength.
CAUTION
The casing of the SolarMax MT series inverter complies with protection class
IP65. Thus, it can be installed outdoors, but the stated IP protection is only
ensured if the included AC connector, an appropriate DC connector (MultiContact
series 4) and the recommended RJ45 communications connectors are used.
When installing outdoors do not expose the inverter to direct sunlight.