95
Operation on LCD
Setting Grid parameters
The default value is the specified value under the current safety regulations. The contents
will be displayed according to the requirements of local laws and regulations. Please refer
to the actual contents displayed on the LCD screen on the inverter.
====Grid Parameters====
>Overvoltage_L1
Undervoltage_L1
OverFreq_L1
Setting Charger
The inverter is compatible with lithium-ion battery and lead–acid battery. You can set the
charge & discharge parameters of battery.
Setting lead-acid battery: Select the battery type of Lead Acid and set the corresponding
parametes.
====Advance Setting====
Grid Parameters
>Charger
Export Control
======Charger======
>Battery Type
Lead Acid
Charge Equalization: Default: 260 V; range: 160-800 V
Charge the battery with the maximum charging current until the battery voltage
reaches the set Charge Equalization and then the current will be gradually
reduced.
======Charger======
>Charge Equalization
00.0V
Charge float: Default: 270 V; range: 160-800 V
Charging the battery with the set Charge float and the battery SOC will be
replenished with a small current.
======Charger======
>Charge float
00.0V
Discharge Cut: Default: 240 V; range: 160-800 V
In modes other than the Backup mode, the battery does not continue to
discharge when the voltage drops to the set Discharge Cut.
======Charger======
>Discharge Cut
00.0V
Discharge BackUp: Default: 245 V; range: 160-800 V
In the Backup mode, the battery does not continue to discharge when the voltage
drops to the set Discharge BackUp.

Table of Contents