169
Appendix
Meter 1
Meter 2
Connect to Meter/
CT terminal
Waterproof
enclosure
Figure 15-39 Connecting to RJ45 splitter adapter
Setting procedures for two direct-connected meters
How to set the parameters of meter 1 and meter 2
a. Select Menu>Setting>Advance Setting>Meter/CT Setting and enter the Meter/
CT Setting interface according to the setting path.
b. Enable the meter 1 selection and set the meter address and direction. You can
check the connection status in Meter/CT Check.
====Meter/CTSetting====
>Select
Meter
====Meter/CTSetting====
>Select
Enable
====Meter/CTSetting====
>Meter 1 Addr
1
====Meter/CTSetting====
>Meter 1 Direction
Positive
c. Enable the meter 2 selection and set the meter address and direction.
====Meter/CTSetting====
>Meter 2 Addr
2
====Meter/CTSetting====
>Meter 2 Direction
Positive