171
Appendix
Figure 15-41 Accessories list
Item Description Quantity Source
A DTSU666
1 set Delivered with meter (Optional)B Two-core network cable
C RJ45 terminal
D RJ45 terminal 1 pc Delivered with inverter
E CT 1 pc Delivered with inverter
F RJ45 splitter adapter 1 pc Prepared by user
G CAT5E network cable 1 pc Prepared by user
H Copper wire / Prepared by user
F
Waterproof connectors
with RJ45
1 pc Delivered with inverter
Wiring procedures for CT and direct-connected meter
a. Connect the meter, CT and inverter. For detailed steps, see "15.6.2 Connection
of Direct-connected Meter" and "15.6.1 Connection of CT". Please note that the
RJ45 splitter adapter should be placed in a proper waterproof enclosure.
Meter 2
Connect to
Meter/CT terminal
Waterproof
enclosure
CT
Figure 15-42 Connecting to RJ45 splitter adapter