37
Mechanical Installation
Step 6: Lift up the inverter collaboratively by the required number of personnel in
accordance with the local regulation and hang it onto the bracket. Make sure that
the hanging slot of the inverter are properly inserted into the lug of the bracket.
Figure 7-9 Hanging the inverter
Step 7: Use M5 screws (part C) to secure the inverter on the bracket.
M5
2.0±0.2 N·m
Figure 7-10 Securing the inverter
Step 8: (Optional) For safety reason, install an anti-theft lock. The anti-theft lock is not in
the scope of delivery. If necessary, prepare a lock with a diameter smaller than Ø7
mm by yourself, and keep the key to the lock in a safe place.
Figure 7-11 Locking the inverter