71
Electrical Connection
LAN mode:
a. Disassemble the waterproof connector into components 1, 2, 3 and 4;
Component 1 is not used. Keep it in a safe place.
1
2
3
4
Figure 8-57 Disassembling the waterproof connector
b. Assemble the dongle.
M2.5
0.8 ± 0.1 N·m
Figure 8-58 Assembling the dongle
c. Plug the dongle to the inverter.
Figure 8-59 Connecting to the inverter