87
Operation on LCD
Setting Self Use Mode
Please refer to "2.7.1 Self-use Mode" for working logic of this mode.
• Min SOC: Default: 10%; range: 10%~100%
»
The minimum SOC of the battery. The battery will not discharge power when
the SOC of the battery reaches this value.
=====User Setting=====
EPS Mute
>Self Use Mode
Feed-in Priority
====Self Use Mode====
>Min SoC
10%
• Charge from grid:
»
You can set whether the power can be taken from the grid to charge the
battery in the forced charing period. When Charge from grid is set to Enable,
the grid power is allowed to charge the battery; when it is set to Disable, the
grid power is not allowed to charge the battery.
====Self Use Mode====
Min SoC
>Charge from grid
====Self Use Mode====
Charge from grid:
> Enable <
• Charge battery to: Default: 10%; range: 10%~100%
»
Set the target SOC to charge the battery from grid in the forced charging
period (applicable only when the Charge from grid is enabled).
»
You can set your own target value, i.e. during the forced charging period,
the inverter will use both PV & grid power to charge the battery to the target
value. If the PV power is still sufficient (enough for load and there is excess
power), the inverter will continue to charge the battery.
====Self Use Mode====
>Charge battery to
10%
Setting Feed-in Priority
Please refer to "2.7.2 Feed-in Priority" for working logic of this mode.
• Min SOC: Default: 10%; range: 10%~100%
»
The minimum SOC of the battery. The battery will not discharge power when
the SOC of the battery reaches this value.
=====User Setting=====
Self Use Mode
>Feed-in Priority
Backup Mode
====Feedin Priority====
>Min SoC
10%
• Charge battery to: Default: 50%; range: 10%~100%
»
Set the target SOC to charge the battery from grid in the forced charging
period.