88
Operation on LCD
»
You can set your own target value, i.e. during the forced charging period,
the inverter will use both PV & grid power to charge the battery SOC to the
target SOC value, after the battery SOC meets the target value, if the PV
power is still sufficient, the surplus power will be fed into the grid.
====Feedin Priority====
>Charge battery to
50%
Setting Backup Mode
Please refer to "2.7.3 Backup Mode" for working logic of this mode.
Min SOC: Default: 30%; range: 30%~100%
»
The minimum SOC of the battery The battery will not discharge power when
the SOC of the battery reaches this value.
=====User Setting=====
Feed-in Priority
>Backup Mode
Char&Disc Period
====Backup Mode====
>Min SoC
30%
Charge battery to: Default: 50%; range: 30%~100%
»
In this mode, the charge from grid function is turned on by default, and
customers can set the target value by themselves, that is, during the forced
charging period, the inverter will use both PV & grid power to charge the
battery to the target value. If the PV power is still sufficient (enough for load
and there is excess power), the inverter will continue to charge the battery.
====Backup Mode====
>Charge battery to
50%
Setting Char&Disc Period
Here you can set the Forced Charge Perid and Allowed Discharge Period.
If two charging and discharging periods are needed, enable the Function Control to
activate the Char&Disc Period2.
Char&Disc Period: You can set the charge and discharge time according to your
own needs. The default time axis of the system is 24h.
»
Forced Charge Period Start Time: Time to start charging; default: 00:00;
range: 00:00~23:59
»
Forced Charge Period End Time: Time to stop charging; default: 00:00;
range: 00:00~23:59
»
Allowed Disc Period Start Time: Time allows to start discharging (The
charging or discharging of the battery depends on the working mode.);
default: 00:00; range: 00:00~23:59

Table of Contents