Setting
Setting
102
103
Select
Meter CT
CT/Meter Setting
Meter 1Addr:
1
CT/Meter Setting
Select
EnableDisable
CT/Meter Setting
Meter 2 Addr:
2
CT/Meter Setting
Meter 1Direction:
Positive Negative
CT/Meter Setting
Meter 2 Direction:
Positive Negative
CT/Meter Setting
5 ) Meter/CT Settings
The user needs to select the CT or electricity meter to connect the
inverter here. CT is a default, when users choose CT, there is only Meter 2
Addr setting. All will show on the inverter screen when users choose
Meter.
4 ) Export Control
This feature allows the inverter to control the amount of electricity
output to the grid.
The factory value is the default and can be changed by the user. The
user value set by setup must be less than the maximum. If the user
does not want to supply power to the grid, set it to 0.
User value:
0W
Export Control
Battery Type
Lead Acid Lithium
Charger
Lead Acid
Charger
Charge Equalization
00.0V
Charger
Charger
Charge float
00.0V
Discharge Cut
00.0V
Charger
Charger
Discharge BackUp
00.0V
>Max Charge
Current:
30A
Charger
Charger
>Max Discharge
Current:
30A
Charge upper limit
100%
Charger
Charger
Lithium
>Max Charge
Current:
30A
Charger
Charger
>Max Discharge
Current:
30A
Charge upper limit
100%
Charger
CT Type
100A/200A
CT/Meter Setting
External INV
Disable Enable
CT/Meter Setting
Meter/CT Check
Disable Enable
CT/Meter Setting
CT status: Disable
CT status: Checking
CT status: Success
CT/Meter Setting
3 ) Charger
Here the user can set the parameters of charger on this page, the
inverter is compatible with both lithium battery. Users can set the
charge & discharge parameters.
For the detailed parameters, please refer to below table.