95
Operation on LCD
=====User Setting=====
Peak shaving mode
>Load Management
User PassWord
===Load Management===
>Mode Select
Disable
===Load Management===
>Mode Select
Manual
===Load Management===
>Mode Select
SmartSave
»
Mode 1 Disable: The Adapter Box function is disabled under this operation
mode.
»
Mode 2 Manual: In this operating mode, you can change the Adapter Box
from on to off, or from off to on through settings on the inverter or through
SolaX App.
»
Mode 3 SmartSave: In this operating mode, users can set a series of
parameters on the SolaX inverter to intelligently control how and when the
heat pump works for them. (see Step C)heat pump works for them. (see Step
C)
c. Set the parameters for mode SmartSave. In this mode, you can set Thresholds
on Feedin power, Thresholds off Consumption, Thresholds off Battery SOC,
Mnimum duration per on-signal, Minimum duration per day and Schedule in
accordance with your actual needs.
===Load Management===
>Mode Select
SmartSave
===Load Management===
>Theresholds on
Feedin power
3000W
===Load Management===
>Minimum duration
per on-signal
5M
===Load Management===
>Theresholds off
Consumption
3000W
===Load Management===
>Minimum duration
per day
900M
===Load Management===
>Theresholds off
Battery SoC
40%
===Load Management===
>Schedule
Enable
Setting thresholds on/off
»
Thresholds on Feedin power: Once the feed-in power is greater than or
equal to the set value, the Adapter Box will turn on and the heat pump will
heat the water up to a higher temperature.
»
Thresholds off Consumption: Once the power consumption (from the grid)
is greater than or equal to the set value, the Adapter Box will be turned off,
SolaX system stops providing electricity to heat pump.
»
Thresholds off Battery SOC: Once the battery SOC drops to the set value,
the Adapter Box will turn off, SolaX system stops providing electricity to heat
pump.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-ULT-15KP and is the answer not in the manual?

SolaX Power X3-ULT-15KP Specifications

General IconGeneral
BrandSolaX Power
ModelX3-ULT-15KP
CategoryInverter
LanguageEnglish

Related product manuals