EasyManuals Logo

SolaX Power X3-ULT-15KP User Manual

SolaX Power X3-ULT-15KP
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
94
Operation on LCD
the grid exceeds the set PeakLimit value, the battery is allowed to discharge
power. The excess power beyond the limit is provided by the combination of
photovoltaic and battery to ensure that the maximum power purchased from
the grid does not exceed the set limit.
»
Peaklimits: Default: 1000 W
====TOU====
Current Mode:
Peak Shaving
==Peak shaving==
Peaklimits:
1000 W
»
Charging: The power of PV will charge the battery as much as possible to
the set SOC of Charge BAT to (%). You can set whether to Charge from grid.
The default value of Charge BAT to (%) is 100%. When the battery reaches the
set SOC, the surplus power will perform "Self-use Mode" or supply to the grid (
based on the system setup), at this point, Charge from grid is not allowed.
»
Charge from grid: Default: Disable
»
Charge BAT to: Default: 100%
==Charging==
Charge from grid:
Disable
Current Mode:
Charging
====TOU====
==Charging==
Charge BAT to:
100%
»
Discharging: If allowed by the battery, the system outputs a specified power
from the grid based on the set output percentage, controlling the power at
the AC port. You need to set the RatePower (%) through Web or App when
choosing Discharging mode. When the battery Discharge to (%) reaches the
set SOC, the inverter performs "Self-use Mode".
»
Rate of AC Power: Default: 100%
»
Discharge to: Default: 10%
Current Mode:
====TOU====
==Discharging==
Rate of AC Power:
100%
Discharging
==Discharging==
Discharge to:
10%
Setting Load Management
To use the heat pump function, you need to set the relevant parameters on LCD screen.
This is function is applicable for the first generation of SolaX Adapter Box.
a. Enter the Load Management interface through the path: Menu>Setting>User
Setting>Load Management
b. Set the Load Management mode. Overall three heat pump operation modes are
available for you to choose:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-ULT-15KP and is the answer not in the manual?

SolaX Power X3-ULT-15KP Specifications

General IconGeneral
BrandSolaX Power
ModelX3-ULT-15KP
CategoryInverter
LanguageEnglish

Related product manuals