118
Troubleshooting and Maintenance
Error Code Fault Descriptions and Diagnosis
IE 33 ParallelFault
Parallel Fault
Check the communication and earth cable
connection and matching resistor settings.
Or contact SolaX for help if it can not return to
normal.
IE 36 HardLimitFault
HardLimitFault
Check the power value set in the HardLimit setting,
increase the value larger if needed.
Or contact SolaX for helpif it can not return to
normal.
IE 37 CTMeterConFault
CT Meter ConFault
Check if the CT or meter is well connected.
Or contact SolaX for help if it can not return to
normal.
IE 101 PowerTypeFault
Power type fault
Upgrade the software and press the ESC key to
restart the inverter.
Or contact SolaX for help if it can not return to
normal.
IE 102 Port OC Warning
EPS(Off-grid) port overcurrent fault
Check if the EPS(Off-grid) load exceeds the system
requirements, and press the ESC key to restart the
inverter. .
Or contact SolaX for help if it can not return to
normal.
IE 103 Mgr EEPROM Fault
Manager EEPROM Fault.
Shut down photovoltaic ,battery and grid, and then
reconnect.
Or contact SolaX for help if it can not return to
normal.
IE 105 NTC Sample Invalid
NTC invalid
Make sure the NTC is properly connected and the
NTC is in good condition.
Please confirm that the installation environment is
normal
Or contact SolaX for help if it can not return to
normal.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-ULT-15KP and is the answer not in the manual?

SolaX Power X3-ULT-15KP Specifications

General IconGeneral
BrandSolaX Power
ModelX3-ULT-15KP
CategoryInverter
LanguageEnglish

Related product manuals