132
Technical Data
Model X3-ULT-15K X3-ULT-19.9K X3-ULT-20K X3-ULT-25K X3-ULT-30K
Max. AC current
[A](above rated
current, de-rating
is acceptable)
(230V)
24.0 29.0 31.9 39.9 43.5
Displacement
power factor
1 (-0.8 ~ 0.8)
Total harmonic
distortion (THDi,
rated power)
< 3%
Maxinum out fault
current [A]
175 175 175 175 175
Maximum output
overcurrent
protection [A]
181 181 181 181 181
• INPUT AC
Model X3-ULT-15K X3-ULT-19.9K X3-ULT-20K X3-ULT-25K X3-ULT-30K
Norminal AC
power [VA]
15000 19999 20000 25000 30000
Norminal AC
current [A]
21.8 29.0 29.0 36.3 43.5
Rated grid
voltage (AC
voltage range) [V]
3P4W, 400 / 230, 380/220
Rated grid
Frequency [Hz]
50 / 60
• BATTERY
Model X3-ULT-15K X3-ULT-19.9K X3-ULT-20K X3-ULT-25K X3-ULT-30K
Battery type Lithium - ion
Battery voltage
range [V]
180 - 800
Max.charge /
discharge power
[kW]
15 / 15 20 / 20 20 / 20 24 / 24 30 / 30
Max.charge
/ discharge
current [A] (30A
max @180-300V)
60 (30 * 2) 60 (30 * 2) 60 (30 * 2) 60 (30 * 2) 60 (30 * 2)
Number of
connectable
batteries
2 2 2 2 2
• EPS OUTPUT (WITH BATTERY)
Model X3-ULT-15K X3-ULT-19.9K X3-ULT-20K X3-ULT-25K X3-ULT-30K
EPS peak power
[VA]
2 time of rated power, 10s
EPS rated power
[VA]
15000 19999 20000 25000 30000