19
Product Overview
Period B & D
Grid consumption power < PeakLimits
(PV + grid
→
load)
• The PV and grid will power the load. The battery will not charge or
discharge power.
Grid consumption power
>
PeakLimits
(PV + battery + grid
→
load)
• The battery will discharge energy for loads and thus reduce the
amount of energy purchased from the grid.
Period C
(PV
→
battery
→
load
→
grid)
• The battery does not discharge power. The PV charges the battery up
to the Reserved SOC before supplying power to the loads. Any excess
power beyond the load requirements is first supplied to the loads, and
then fed into the grid.
Note:
MaxSOC: The energy taken from grid to charge the battery. 50% by default, the settable
range is 10%-100%.
ChargePowerLimits: The charging power from grid. 1000 W by default, the settable range
is 0-60000 W
PeakLimits: The load consumption from grid side. 0 W by default, the settable range:
0-60000 W.
Reserved SOC: The lower limit of battery SOC required for later peak shaving period. 50%
by default, the settable range is 10~100%.
2.7.5 Schedule Mode
In the Schedule mode, different working modes, i.e Self-use, Feed-in Priority, Peaking
shaving, Charging and Discharging can be set for different time slots in accordance with
actual needs and environment conditions through SolaX Cloud App or Web. The day is
divided into 24 time slots, each representing one hour. independent working mode can be
set for each time slot. Please refer to
Web Guide
or
App Guide
for details about how to set
the Schedule mode.
Time Slot Working Mode
0:00~1:00
Choose one mode from Self-use
/
Feed-in Priority / Peaking shaving /
Charging / Discharging
1:00~2:00
Choose one mode from Self-use
/
Feed-in Priority / Peaking shaving /
Charging / Discharging
.
.
.
.
.
.
21:00~22:00
Choose one mode from Self-use
/
Feed-in Priority / Peaking shaving /
Charging / Discharging