8 Translation of I-V Data to Standard Test Conditions
8-3
The translation equations are as follows, where the subscripts are defined as m =
measured, and trans = translated:
I
sctrans
= I
scmeas
* (E
trans
/ E
meas
) / (1 + (α
Isc
/100) * (T
meas
- T
trans
))
V
octrans
= V
ocmeas
/ (1 + (β
Voc
/ 100) * (T
meas
- T
trans
))
I
mptrans
= I
mpmeas
* (E
trans
/ E
meas
)
V
mptrans
= V
mpmeas
/ (1+ (γ
mpp
/ 100) * (T
meas
- T
trans
))
P
mptrans
= P
mpmeas
* [E
trans
/ E
meas
] / (1+ (γ
mpp
/ 100) * (T
meas
- T
trans
))