Value
Value
Cable requirements:
Type 2 DC connector:
Assemble the DC connectors as described in the following.
Assemble the DC connectors as described below. Be sure to observe the correct polarity. The DC
connectors are marked with the symbols  and .
Complete the installation.
4
5
3
2
External diameter
Conductor cross-section
Number of copper wires
5-8mm
Description Value
Item
1
Cable type
PV1-F, UL-ZKLA or USE2
2.5-6mm²
At least 7
The rated voltage
 v
Step 3Push the swivel nut u to the thread and tighten the swivel nut. SW, Torue .m
A B
+
1
2
UM0035_ASW05-12kH-T2-T3_EN_V01_0523
45