4-7
DNW-A220
DNW-A220P
4-2. Cleaning
Stationary Heads and Tape Cleaner Cleaning
4-2-5. Stationary Heads and Tape Cleaner Cleaning
Warning
The tape cleaner has sharp edge. Do not touch the edge with bare hands. Pay careful attention when
cleaning the tape cleaner.
Caution
. Be careful not to damage the head surface when cleaning the stationary heads.
Tools
. Cleaning cloth: 3-184-527-01
. Cleaning fluid: 9-919-573-01
Procedures
1. Clean the tape running surfaces of the full-erase head, tape cleaner, CTL head, AT erase head and AT
head in the vertical direction with a cleaning cloth moistened with a cleaning fluid.
m
. An error may occur in the playback or recording when magnetic powder attaches to the head gap
portion of the full-erase head, CTL head, AT erase head or AT head. Remove the magnetic powder
completely during cleaning.
. Do not touch the edge portion of the tape cleaner with bare hands.
. Pay careful not to damage the tape cleaner.
2. After cleaning, wipe them with a dry cleaning cloth two or three times.
CTL head
Full-erase head
Tape cleaner
DNW-A220 (SY) S/N 31001 through 31320
DNW-A220P (SY) S/N 31001 through 31549
CTL head
Full-erase head
Tape cleaner
AT erase head
AT head
51001 through 51320
51001 through 51549
DNW-A220 (SY) S/N 31321 and higher
DNW-A220P (SY) S/N 31552 and higher
51321 and higher
51552 and higher

Table of Contents