3-16
DNW-A220
DNW-A220P
C001 : CASSETTE COMP. LOCK SW
This submenu checks the locking switch function of a compartment.
(1) Push down the cassette compartment.
. Confirm that the message on the LCD monitor from “OFF” to “ON!”.
(2) Push the MENU button when terminating the check.
In case of NG
. Check the cassette compartment down sensor on the SV-194 board.
. Check the sensor input port of CPU (IC304 on the SV-194 board).
3-2. TAPE Maintenance Mode (M0)
3-2-2. SERVO CHECK Mode (C0)
Cassette compartment down sensor
INPUT CHECK
C001:CASSETTE COMP. SW
OFF
INPUT CHECK
C001:CASSETTE COMP. SW
ON!
Cassette compartment down sensor